Click for
Table of Contents

menuES-10X Quick Start Guide

Package Contents

EdgeSwitch 10X
Wall Mount Screws (Qty. 2)
Wall Mount Anchors (Qty. 2)
Ground Screw
Power Adapter (24V, 1A)
Cable Clip

Installation Requirements

Note: Although the cabling can be located outdoors, the EdgeSwitch itself should be housed inside a protective enclosure.

Hardware Overview

System LED

Flashing White

Bootup in Progress

White

Ready for Use

Not Connected to Ubiquiti Internet Service Provider (UISP)

Blue

Ready for Use

Connected to UISP

Steady Blue with Occasional Flashing

Ready for Use

Unable to Connect to UISP

Quickly Flashing Blue

Used to Locate a Device in UISP

Alternating Blue/White

Firmware Upgrade in Progress

RJ45 Speed/Link/Activity LED (Ports 1 - 8)

Off

No Link

Amber

Link Established at 10/100 Mbps

Flashing Indicates Activity

Green

Link Established at 1000 Mbps

Flashing Indicates Activity

SFP Link/Activity LED (Ports 9 - 10)

Off

No Link

Green

Link Established at 1 Gbps

Flashing Indicates Activity

RJ45 (Ports 1 - 8)

RJ45 ports support 10/100/1000 Ethernet connections.

  • PoE In (Port 1) Supports 24V Passive PoE input.
  • PoE Out (Port 8) Supports 24V Passive PoE passthrough.

SFP (Ports 9 - 10)

Hot-swappable SFP ports support 1 Gbps connections. If you use a copper Ethernet module (example: UF-RJ45-1G), power off the EdgeSwitch before insertion; otherwise there may be a device reboot.

Reset Button

To reset to factory defaults:

  1. Disconnect power from the EdgeSwitch.
  2. Reconnect power while holding the Reset button. The port LEDs will light up in sequential order (this takes approximately five seconds).
  3. When the port 1 LED flashes again, release the Reset button.

Power

Connect the included Power Adapter to the Power port.

Grounding Point

Ground bonding point for an optional ground wire.

Hardware Installation

The optional EdgeRouter Rackmount Kit, model ER-RMKIT, is sold separately.

WARNING: The EdgeSwitch ES-10X must not be stacked. Do not place it on top of another switch. Do not place anything on top of the ES-10X.

Wall Mounting

Grounding the EdgeSwitch (Recommended)

The Power Adapter grounds the device; however, you can add optional ESD grounding for enhanced ESD protection (ground wire not included).

Optional

Connecting Power

Note: Only one power source can be used at any one time. With both power sources connected, the input with the highest voltage will be used; the other power source defaults to backup.

OR

Connecting Ethernet

WARNING: Before enabling PoE passthrough, ensure that the connected PoE device supports 24V Passive PoE.

Using SFP Ports

For information about compatible fiber SFP modules, visit: ubnt.link/SFP_DAC_Compatibility

Accessing the Configuration Interface

The device is set to DHCP by default, so it will try to automatically obtain an IP address. If that fails, then it will use the default fallback IP address, 192.168.1.20. Proceed to the appropriate section, DHCP or “Fallback IP Address”:

DHCP

Use one of the following methods:

To log in, follow these steps:

  1. Launch your web browser. Type the appropriate IP address in the address field. Press enter (PC) or return (Mac).
  2. Enter ubnt in the Username and Password fields. Click Sign In.

The EdgeSwitch Configuration Interface will appear. Customize additional settings as needed. For 24V Passive PoE configuration, refer to “Configuring PoE Settings”. For more information, refer to the EdgeSwitch documentation, which is available at ui.com/download/edgemax

Fallback IP Address

  1. Ensure that your computer (or other host system) is connected to the device.
  2. Configure the Ethernet adapter on your host system with a static IP address on the 192.168.1.x subnet.
  3. Launch your web browser. Type the appropriate IP address in the address field (192.168.1.20 is the default fallback IP address). Press enter (PC) or return (Mac).

  4. Enter ubnt in the Username and Password fields. Click Sign In.
  5. The EdgeSwitch Configuration Interface will appear. Click the System Settings tab.
  6. Change the IP Address to a unique IP address. Click Apply.

Note: If you change the IP settings, then the session will be cut off, and you will need to reconnect to the device using the new IP address.

Customize additional settings as needed. For 24V Passive PoE configuration, refer to “Configuring PoE Settings”. For more information, refer to the EdgeSwitch documentation, which is available at ui.com/download/edgemax

Configuring PoE Settings

The PoE setting for port 8 is set to Off by default.

WARNING: Before activating PoE, ensure that the connected device supports passive PoE and the supplied voltage.

On the Dashboard tab, click the PoE setting of port 8. Then select 24V.

UISP Management

You can manage your device using UISP, which lets you configure, monitor, upgrade, and back up your devices using a single application. Get started at uisp.ui.com

Specifications

ES-10X

Dimensions

207 x 31.1 x 90 mm (8.15 x 1.22 x 3.54")

Weight

500 g (1.10 lb)

Total Non-Blocking Throughput

10 Gbps

Switching Capacity

20 Gbps

Forwarding Rate

14.88 Mpps

Max. Power Consumption
(Excluding PoE Output)

8W

Power Method

24VDC, 1A or
24V Passive PoE

Supported Voltage Range

9 -30VDC

Power Supply

24VDC, 1A Power Adapter (Included) or
24V Passive PoE

LEDs

 

System Status
RJ45 Data Ports Link/Speed/Activity
SFP Data Ports Link/Activity

Networking Interfaces

(8) 10/100/1000 Mbps RJ45 Ports

(2) 1 Gbps SFP Ports

Management Interface

Ethernet In-Band

Certifications

CE, FCC, IC

ESD/EMP Protection

Air: ± 24 kV, Contact: ± 24 kV

Operating Temperature

-10 to 50° C (14 to 122° F)

Operating Humidity

5 to 95% Noncondensing

Shock and Vibration

ETSI300-019-1.4 Standard

PoE (Port 8)

PoE Interface

24VDC Passive PoE (Pins 4, 5+; 7, 8-)

Max. Passive PoE Wattage per Port

15W

24V Passive PoE Voltage Range

24V

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

Warning

WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.

Warning

WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.

Warning

WARNING: Do not use this product in location that can be submerged by water.

Warning

WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
  3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
    1. Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
    2. The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
    3. Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
    4. Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
    5. Protective bonding must be installed in accordance with local national wiring rules and regulations.

Limited Warranty

ui.com/support/warranty

The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada

CAN ICES-3(A)/NMB-3(A)

Australia and New Zealand

RCM

Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.

CE Marking

CE marking on this product represents the product is in compliance with all directives that are applicable to it.

CE

WEEE Compliance Statement

Declaration of Conformity

Online Resources

SupportCommunityDownloads