Click for
Table of Contents

menuUVC-G4-BULLET Quick Start Guide

Package Contents

Camera
Cable Gland
Screw Anchors (Qty. 2)
Self-Tapping Screws (Qty. 2)
Pole Mount Bracket
Machine Screws (Qty. 2)

Installation Requirements

Hardware Overview

Ethernet Port

Gigabit RJ45 port connects to an 802.3af PoE switch for PoE power and data.

Reset Button

To reset to factory defaults, press and hold the Reset button for more than 10 seconds while the camera is powered on.

Hardware Installation

Ceiling Mount

Wall Mount

  1. Note: For outdoor installations, position the Cable Slot downward.

  2.  
  3. OR

    IMPORTANT: If you are installing your camera outdoors, create a drip loop for the cable below the camera to prevent water ingress.

  4. IMPORTANT: For proper weather sealing, the Cable Gland must fit securely within the Adjustable Base when the camera is mounted. Ensure that the Cable Gland is securely seated during installation and cable routing.

Pole Mount

  1. IMPORTANT: Ensure that the Cable Gland is securely seated during installation and cable routing.

Connecting to a PoE Switch

Setting Up UniFi Protect via App

Launch the UniFi Protect Mobile App and follow the on-screen instructions to complete setup.

Adjusting the Camera View

Specifications

UVC-G4-BULLET

Dimensions

Ø 75 x 140 mm (Ø 2.95 x 5.51")

Weight

458 g (1 lb)

Enclosure

Injection-Molded Polycarbonate and
Die-Cast Aluminum

Networking Interface

(1) 10/100/1000 Ethernet Port

Viewing Angle

86° (H), 60° (V), 111° (D)

Night Mode

IR LEDs with Mechanical IR Cut Filter

Video Compression

H.264

Resolution

(4MP) 2688 x 1520

Maximum Frame Rate

24 FPS

Image Settings

Brightness, Contrast, Sharpness, Saturation, Noise Reduction, 50/60 Hz

Processor

Ambarella S5L55m

Memory

512 MB DDR3L

Management Interface

UniFi Protect

Microphone

Yes

Max. Power Consumption

4W

Power Method

802.3af

Power Supply

802.3af PoE Switch

Buttons

Factory Reset Button

Mounting

Wall/Ceiling/Pole (Kits Included)

Operating Temperature

-20 to 40° C
(-4 to 104° F)

Operating Humidity

0 to 90% Noncondensing

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

Warning

WARNING: Hot surface. Do not touch.

Warning

WARNING: Do not use this product in location that can be submerged by water.

Warning

WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information

  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.

Limited Warranty

ui.com/support/warranty

The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada

CAN ICES-3(A)/NMB-3(A)

Australia and New Zealand

RCM

Warning: This equipment is compliant with Class A of CISPR 32. In a residential environment this equipment may cause radio interference.

CE Marking

CE marking on this product represents the product is in compliance with all directives that are applicable to it.

CE

WEEE Compliance Statement

Declaration of Conformity

Online Resources

SupportCommunityDownloads